TY - JOUR
T1 - Bioprosthetic valve dysfunction and failure after TAVI in bicuspid aortic valve stenosis during one-year follow-up according to VARC-3
AU - Veulemans, Verena
AU - Nuyens, Philippe
AU - Goh, Shouheng
AU - Maier, Oliver
AU - Binnebößel, Stephan
AU - Heermann, Jacqueline
AU - Jung, Christian
AU - Westenfeld, Ralf
AU - Kelm, Malte
AU - de Backer, Ole
AU - Zeus, Tobias
N1 - © 2022. The Author(s).
PY - 2022/12
Y1 - 2022/12
N2 - BACKGROUND: Transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) stenosis has become more frequent in the last years. This may pose challenges for long-time valve durability. Therefore, we aimed to evaluate the prevalence of bioprosthetic valve dysfunction (BVD) with the newest-generation devices in BAV stenosis up to one-year follow-up (FU).METHODS: The primary endpoint was defined as the prevalence of BVD during the first procedural year according to Valve Academic Research Consortium (VARC)-3 criteria. Secondary endpoints were defined as failure in device success and clinical endpoints according to VARC-3.RESULTS: A total of 107 patients were included. Of these, 34 subjects (31.8%) met the criteria for BVD during a mean FU of 263 ± 180 days, of which 20.2% were already documented after thirty days. Device success after one year was lower in the + BVD cohort (57.6% vs. 98.7%, p < 0.0001*). The rates of structural valve deterioration were 6.5%, non-structural valve deterioration (NSVD) 17.8%, subclinical leaflet thickening 10.3%, and endocarditis 0.9%. NSVD was foremost triggered by patient prosthesis mismatch in balloon-expandable valves. Hemodynamic valve deterioration stage 1 and 2 was confirmed in 16.8% of + BVD patients, while stage 1 and 3 bioprosthetic valve failure occurred in 1.9%. There was no impact of BVD on mortality.CONCLUSION: There is critical evidence of early BVD after TAVI in BAV during one-year FU in one-third of patients, also lowering device success. The most frequently observed bioprosthetic valve dysfunction was NSVD due to patient prosthesis mismatch following TAVI with a balloon-expandable valve.
AB - BACKGROUND: Transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) stenosis has become more frequent in the last years. This may pose challenges for long-time valve durability. Therefore, we aimed to evaluate the prevalence of bioprosthetic valve dysfunction (BVD) with the newest-generation devices in BAV stenosis up to one-year follow-up (FU).METHODS: The primary endpoint was defined as the prevalence of BVD during the first procedural year according to Valve Academic Research Consortium (VARC)-3 criteria. Secondary endpoints were defined as failure in device success and clinical endpoints according to VARC-3.RESULTS: A total of 107 patients were included. Of these, 34 subjects (31.8%) met the criteria for BVD during a mean FU of 263 ± 180 days, of which 20.2% were already documented after thirty days. Device success after one year was lower in the + BVD cohort (57.6% vs. 98.7%, p < 0.0001*). The rates of structural valve deterioration were 6.5%, non-structural valve deterioration (NSVD) 17.8%, subclinical leaflet thickening 10.3%, and endocarditis 0.9%. NSVD was foremost triggered by patient prosthesis mismatch in balloon-expandable valves. Hemodynamic valve deterioration stage 1 and 2 was confirmed in 16.8% of + BVD patients, while stage 1 and 3 bioprosthetic valve failure occurred in 1.9%. There was no impact of BVD on mortality.CONCLUSION: There is critical evidence of early BVD after TAVI in BAV during one-year FU in one-third of patients, also lowering device success. The most frequently observed bioprosthetic valve dysfunction was NSVD due to patient prosthesis mismatch following TAVI with a balloon-expandable valve.
KW - Aortic Valve Stenosis/diagnosis
KW - Aortic Valve/diagnostic imaging
KW - Bicuspid Aortic Valve Disease
KW - Constriction, Pathologic
KW - Follow-Up Studies
KW - Heart Valve Diseases/diagnosis
KW - Heart Valve Prosthesis
KW - Humans
KW - Mitral Valve Stenosis
KW - Transcatheter Aortic Valve Replacement
KW - Treatment Outcome
KW - Bicuspid valves
KW - TAVI
KW - Bioprosthetic valve dysfunction
KW - Device success
KW - Complication
KW - Elderly
UR - http://www.scopus.com/inward/record.url?scp=85133169809&partnerID=8YFLogxK
U2 - 10.1007/s00392-022-02052-9
DO - 10.1007/s00392-022-02052-9
M3 - Journal article
C2 - 35767098
SN - 1861-0684
VL - 111
SP - 1358
EP - 1366
JO - Clinical research in cardiology : official journal of the German Cardiac Society
JF - Clinical research in cardiology : official journal of the German Cardiac Society
IS - 12
ER -