Awareness during emergence from anaesthesia: significance of neuromuscular monitoring in patients with butyrylcholinesterase deficiency

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Minimising droplet and virus spread during and after tracheal extubation

    Publikation: Bidrag til tidsskriftLetterForskningpeer review

  2. Enhanced recovery after surgery components and perioperative outcomes: a nationwide observational study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Sphenopalatine ganglion block for the treatment of postdural puncture headache: a randomised, blinded, clinical trial

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Use of the GRADE approach in systematic reviews and guidelines

    Publikation: Bidrag til tidsskriftLederForskningpeer review

  1. Minimising droplet and virus spread during and after tracheal extubation

    Publikation: Bidrag til tidsskriftLetterForskningpeer review

  2. Barriers and aidsto routine neuromuscular monitoring and consistent reversal practice: - a qualitative study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Reversal of mivacurium-induced neuromuscular blockade with a cholinesterase inhibitor: A systematic review

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Deep neuromuscular blockade and surgical conditions during laparoscopic ventral hernia repair: A randomised, blinded study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

BACKGROUND: Butyrylcholinesterase deficiency can result in prolonged paralysis after administration of succinylcholine or mivacurium. We conducted an interview study to assess whether patients with butyrylcholinesterase deficiency were more likely to have experienced awareness during emergence from anaesthesia if neuromuscular monitoring had not been applied.

METHODS: Patients referred during 2004-2012 were included. Data on the use of neuromuscular monitoring were available from a previous study. Interviews, conducted by telephone, included questions about awareness and screening for post-traumatic stress disorder. Reports of panic, hopelessness, suffocation, or a feeling of being dead or dying resulted in the experience being classified further as distressful. Patients were categorized as aware or unaware by investigators blinded to use of neuromuscular monitoring.

RESULTS: Ninety-five patients were eligible to be interviewed. Of the 70 patients interviewed, 35 (50%) were aware while paralysed during emergence. Of these, 28 (80%) were not monitored with a nerve stimulator when awakened, compared with 17 (49%) of the 35 unaware patients (P=0.012, Fisher's exact test). Thirty (86%) aware patients reported distress compared with seven (20%) unaware patients (P<0.001). The aware patients scored higher in screening for post-traumatic stress disorder (P=0.006, Mann-Whitney U-test).

CONCLUSIONS: Butyrylcholinesterase deficiency is a major risk factor for distressing awareness during emergence. Lack of neuromuscular monitoring increases the risk significantly. Neuromuscular monitoring should be applied even when using short-acting neuromuscular blocking agents.

OriginalsprogEngelsk
TidsskriftBritish Journal of Anaesthesia
Vol/bind115 Suppl 1
Sider (fra-til)i78-i88
ISSN0007-0912
DOI
StatusUdgivet - jul. 2015

ID: 45902595