Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Automated EEG source imaging: A retrospective, blinded clinical validation study

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Automatic continuous EEG signal analysis for diagnosis of delirium in patients with sepsis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Myelin protein zero gene dose dependent axonal ion-channel dysfunction in a family with Charcot-Marie-Tooth disease

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Automatic detection of cortical arousals in sleep and their contribution to daytime sleepiness

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Comparing Seizure-Related Death and Suicide in Younger Adults with Epilepsy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Sudden unexpected death in epilepsy in persons younger than 50 years: A retrospective nationwide cohort study in Denmark

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Biomarkers for Traumatic Brain Injury: Data Standards and Statistical Considerations

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

OBJECTIVE: To evaluate the accuracy of automated EEG source imaging (ESI) in localizing epileptogenic zone.

METHODS: Long-term EEG, recorded with the standard 25-electrode array of the IFCN, from 41 consecutive patients with focal epilepsy who underwent resective surgery, were analyzed blinded to the surgical outcome. The automated analysis comprised spike-detection, clustering and source imaging at the half-rising time and at the peak of each spike-cluster, using individual head-models with six tissue-layers and a distributed source model (sLORETA). The fully automated approach presented ESI of the cluster with the highest number of spikes, at the half-rising time. In addition, a physician involved in the presurgical evaluation of the patients, evaluated the automated ESI results (up to four clusters per patient) in clinical context and selected the dominant cluster and the analysis time-point (semi-automated approach). The reference standard was location of the resected area and outcome one year after operation.

RESULTS: Accuracy was 61% (95% CI: 45-76%) for the fully automated approach and 78% (95% CI: 62-89%) for the semi-automated approach.

CONCLUSION: Automated ESI has an accuracy similar to previously reported neuroimaging methods.

SIGNIFICANCE: Automated ESI will contribute to increased utilization of source imaging in the presurgical evaluation of patients with epilepsy.

OriginalsprogEngelsk
TidsskriftClinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
Vol/bind129
Udgave nummer11
Sider (fra-til)2403-2410
Antal sider8
ISSN1388-2457
DOI
StatusUdgivet - 1 nov. 2018