TY - JOUR
T1 - Assessment of left ventricular outflow tract and aortic root
T2 - comparison of 2D and 3D transthoracic echocardiography with multidetector computed tomography
AU - Visby, Lasse
AU - Kristensen, Charlotte Burup
AU - Pedersen, Frederik Holm Grund
AU - Sigvardsen, Per Ejlstrup
AU - Kofoed, Klaus Fuglsang
AU - Hassager, Christian
AU - Møgelvang, Rasmus
N1 - Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: [email protected].
PY - 2019/10/1
Y1 - 2019/10/1
N2 - AIMS: Accurate echocardiographic assessment of left ventricular outflow tract (LVOT) and the aortic root is necessary for risk stratification and choice of appropriate treatment in patients with pathologies of the aortic valve and aortic root. Conventional 2D transthoracic echocardiographic (TTE) assessment is based on the assumption of a circular shaped LVOT and aortic root, although previous studies have indicated a more ellipsoid shape. 3D TTE and multidetector computed tomography (MDCT) applies planimetry and are not dependent on geometrical assumptions. The aim was to test accuracy, feasibility, and reproducibility of 3D TTE compared to 2D TTE assessment of LVOT and aortic root areas, with MDCT as reference.METHODS AND RESULTS: We examined 51 patients with 2D/3D TTE and MDCT at the same day. All patients were re-examined with 2D/3D TTE on a different day to evaluate 2D and 3D re-test variability. Areas of LVOT, aortic annulus, and sinus were assessed using 2D, 3D TTE, and MDCT. Both 2D/3D TTE underestimated the areas compared to MDCT; however, 3D TTE areas were significantly closer to MDCT-areas. 2D vs. 3D mean MDCT-differences: LVOT 1.61 vs. 1.15 cm2, P = 0.019; aortic annulus 1.96 vs. 1.06 cm2, P < 0.001; aortic sinus 1.66 vs. 1.08 cm2, P = 0.015. Feasibility was 3D 76-79% and 2D 88-90%. LVOT and aortic annulus areas by 3D TTE had lowest variabilities; intraobserver coefficient of variation (CV) 9%, re-test variation CV 18-20%.CONCLUSION: Estimation of LVOT and aortic root areas using 3D TTE is feasible, more precise and more accurate than 2D TTE.
AB - AIMS: Accurate echocardiographic assessment of left ventricular outflow tract (LVOT) and the aortic root is necessary for risk stratification and choice of appropriate treatment in patients with pathologies of the aortic valve and aortic root. Conventional 2D transthoracic echocardiographic (TTE) assessment is based on the assumption of a circular shaped LVOT and aortic root, although previous studies have indicated a more ellipsoid shape. 3D TTE and multidetector computed tomography (MDCT) applies planimetry and are not dependent on geometrical assumptions. The aim was to test accuracy, feasibility, and reproducibility of 3D TTE compared to 2D TTE assessment of LVOT and aortic root areas, with MDCT as reference.METHODS AND RESULTS: We examined 51 patients with 2D/3D TTE and MDCT at the same day. All patients were re-examined with 2D/3D TTE on a different day to evaluate 2D and 3D re-test variability. Areas of LVOT, aortic annulus, and sinus were assessed using 2D, 3D TTE, and MDCT. Both 2D/3D TTE underestimated the areas compared to MDCT; however, 3D TTE areas were significantly closer to MDCT-areas. 2D vs. 3D mean MDCT-differences: LVOT 1.61 vs. 1.15 cm2, P = 0.019; aortic annulus 1.96 vs. 1.06 cm2, P < 0.001; aortic sinus 1.66 vs. 1.08 cm2, P = 0.015. Feasibility was 3D 76-79% and 2D 88-90%. LVOT and aortic annulus areas by 3D TTE had lowest variabilities; intraobserver coefficient of variation (CV) 9%, re-test variation CV 18-20%.CONCLUSION: Estimation of LVOT and aortic root areas using 3D TTE is feasible, more precise and more accurate than 2D TTE.
KW - 2D transthoracic echocardiography
KW - 3D transthoracic echocardiography
KW - Aortic root
KW - Left ventricular outflow tract (LVOT)
KW - Multidetector computed tomography (MDCT)
U2 - 10.1093/ehjci/jez045
DO - 10.1093/ehjci/jez045
M3 - Journal article
C2 - 30879047
SN - 1525-2167
VL - 20
SP - 1156
EP - 1163
JO - European heart journal cardiovascular Imaging
JF - European heart journal cardiovascular Imaging
IS - 10
ER -