Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

An automated method for determining the cytoadhesion of Plasmodium falciparum-infected erythrocytes to immobilized cells

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Antibiotic prescribing in paediatric inpatients in Ghana: a multi-centre point prevalence survey

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Population Pharmacokinetics of the Antimalarial Amodiaquine: a Pooled Analysis To Optimize Dosing

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Traffic flow and microbial air contamination in operating rooms at a major teaching hospital in Ghana

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Detection of Glycan Shedding in the Blood: New Class of Multiple Sclerosis Biomarkers?

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

BACKGROUND: Plasmodium falciparum exports antigens to the surface of infected erythrocytes causing cytoadhesion to the host vasculature. This is central in malaria pathogenesis but in vitro studies of cytoadhesion rely mainly on manual counting methods. The current study aimed at developing an automated high-throughput method for this purpose utilizing the pseudoperoxidase activity of intra-erythrocytic haemoglobin.

METHODS: Chinese hamster ovary (CHO) cells were grown to confluence in chamber slides and microtiter plates. Cytoadhesion of co-cultured P. falciparum, selected for binding to CHO cells, was quantified by microscopy of Giemsa-stained chamber slides. In the automated assay, binding was quantified spectrophotometrically in microtiter plates after cell lysis using tetramethylbenzidine as peroxidase-catalysed substrate. The relevance of the method for binding studies was assessed using: i) binding of P. falciparum-infected erythrocytes to CHO cells over-expressing chondroitin sulfate A and ii) CHO cells transfected with CD36. Binding of infected erythrocytes including field isolates to primary endothelial cells was also performed. Data was analysed using linear regression and Bland-Altman plots.

RESULTS: The manual and automated quantification showed strong, positive correlation (r(2) = 0.959, p <0.001) and with similar detection limit and precision. The automated assay showed the expected dose-dependent reduction in binding to CHO cells when blocking with soluble chondroitin sulfate A or anti-CD36 antibody. Quantification of binding to endothelial cells showed clear distinction between selected vs. non-selected parasite lines. Importantly, the assay was sufficiently sensitive to detect adhesion of field isolates to endothelial cells.

CONCLUSIONS: The assay is simple and in a reproducible manner quantifies erythrocyte adhesion to several types of immobilized cells.

OriginalsprogEngelsk
TidsskriftMalaria Journal
Vol/bind14
Sider (fra-til)112
ISSN1475-2875
DOI
StatusUdgivet - 2015

ID: 46283956