Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Adherence to instruction for use after endovascular repair of popliteal artery aneurysm

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. The value of 18F-FDG-PET-CT in the management of infective native aortic aneurysms

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Hemodynamic effects of closure of residual arteriovenous fistulae during in situ graft procedures

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. A cross-sectional national study of burnout and psychosocial work environment in vascular surgery in Denmark

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Hyperoxia and Antioxidants for Myocardial Injury in Noncardiac Surgery: A 2 × 2 Factorial, Blinded, Randomized Clinical Trial

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Profiling abdominal aortic aneurysm growth with three-dimensional ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. International Implementation of a PROficiency based StePwise Endovascular Curricular Training (PROSPECT) in Daily Practice

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

OBJECTIVES: Endovascular repair (ER) of popliteal artery aneurysm (PAA) is an alternative to open repair. However, there is no standardized protocol for when to opt for ER and the decision is therefore at the discretion of the clinician. This study aims to evaluate the adherence to the Instruction For Use (IFU) in patients undergoing ER for PAA and factors associated with stent graft patency at one year.

METHODS: The adherence to IFU provided by the manufacturer in 55 patients treated with Gore Viabahn® Endoprosthesis with Heparin Bioactive Surface for PAA between 2009 and 2019 were retrospectively analyzed. Duplex follow-up was performed at 30 days and one year.

RESULTS: The two groups of patients treated within (n = 10) and not within (n = 45) IFU did not differ in patient demographics, diagnostic assessment, treatment or outcome. Forty-five patients (81.8%) received stent graft placement with at least one deviation according to IFU. Distal oversizing >20% was the most frequent deviation against IFU (n = 22, 40.0%). Primary patency at one year was 72%. Diameter size difference >1 mm between overlapping stent grafts (6/14 [43%], p = 0.013) and renal insufficiency (5/12 [42%], p = 0.0086) were associated with lower primary patency at one year. Age-adjusted analysis of tortuosity index (HR 1.78/SD, 95% CI 1.17-2.71; p = 0.0071) and maximal PAA angle (HR 1.73/SD, 95% CI 1.018-2.95; p = 0.043) were associated with major amputation/mortality at end of follow-up.

CONCLUSION: The majority of patients undergoing ER for PAA were not treated within IFU. Diameter size difference >1 mm between overlapping stent grafts was associated with a higher loss of primary patency at one year. Multi-center studies with larger sample size and long-term follow up of patency are warranted.

OriginalsprogEngelsk
TidsskriftVascular
Vol/bind30
Udgave nummer2
Sider (fra-til)276-284
Antal sider9
ISSN1708-5381
DOI
StatusUdgivet - apr. 2022