TY - JOUR
T1 - Accuracy, reproducibility, and comparability of Doppler tissue imaging by two high-end ultrasound systems
AU - Kjaergaard, Jesper
AU - Korinek, Josef
AU - Belohlavek, Marek
AU - Oh, Jae K
AU - Sogaard, Peter
AU - Hassager, Christian
PY - 2006/3
Y1 - 2006/3
N2 - INTRODUCTION: Doppler tissue imaging is a new technology for quantitative evaluation of myocardial motion and contractility, and is available in several ultrasound systems. This study evaluates the comparability, accuracy, and reproducibility of measurements of velocity, strain rate, and strain by two high-end ultrasound systems.METHODS: Accuracy was assessed by imaging a tissue-mimicking gelatin phantom, and the comparability of measurements in the right ventricular free wall and interventricular septum was assessed in 20 healthy participants. Reproducibility was evaluated by repeated recordings in vitro and in a random subset of patients.RESULTS: In vitro, a high degree of accuracy was found in both systems, with one system measuring slightly lower values than the reference values (mean difference 0.35 +/- 0.18 cm/s, P < .001). Values higher than the reference values were measured by both systems for strain and strain rate. In vivo, no systematic differences in measured velocities, strain rate, and strain were found; however, wide limits of agreement were seen for strain and strain rate. Measurements of tissue velocity, strain, and strain rate were well reproducible, nevertheless wide variation was found in both systems (coefficient of variation = 9%-19%).CONCLUSION: For clinical purposes, both systems have sufficient accuracy for measurements of tissue velocity. The variation in measurements of strain rate and strain by Doppler tissue imaging should be taken into account when designing studies using this new technology. Approaches to potentially reduce this variation should be addressed in future studies.
AB - INTRODUCTION: Doppler tissue imaging is a new technology for quantitative evaluation of myocardial motion and contractility, and is available in several ultrasound systems. This study evaluates the comparability, accuracy, and reproducibility of measurements of velocity, strain rate, and strain by two high-end ultrasound systems.METHODS: Accuracy was assessed by imaging a tissue-mimicking gelatin phantom, and the comparability of measurements in the right ventricular free wall and interventricular septum was assessed in 20 healthy participants. Reproducibility was evaluated by repeated recordings in vitro and in a random subset of patients.RESULTS: In vitro, a high degree of accuracy was found in both systems, with one system measuring slightly lower values than the reference values (mean difference 0.35 +/- 0.18 cm/s, P < .001). Values higher than the reference values were measured by both systems for strain and strain rate. In vivo, no systematic differences in measured velocities, strain rate, and strain were found; however, wide limits of agreement were seen for strain and strain rate. Measurements of tissue velocity, strain, and strain rate were well reproducible, nevertheless wide variation was found in both systems (coefficient of variation = 9%-19%).CONCLUSION: For clinical purposes, both systems have sufficient accuracy for measurements of tissue velocity. The variation in measurements of strain rate and strain by Doppler tissue imaging should be taken into account when designing studies using this new technology. Approaches to potentially reduce this variation should be addressed in future studies.
KW - Echocardiography, Doppler/instrumentation
KW - Equipment Design
KW - Equipment Failure Analysis
KW - Female
KW - Heart Ventricles/diagnostic imaging
KW - Humans
KW - Image Enhancement/instrumentation
KW - Image Interpretation, Computer-Assisted/instrumentation
KW - Male
KW - Middle Aged
KW - Phantoms, Imaging
KW - Reproducibility of Results
KW - Sensitivity and Specificity
KW - Stress, Mechanical
KW - Stroke Volume
KW - Ventricular Function
KW - Ventricular Function, Left/physiology
U2 - 10.1016/j.echo.2005.10.007
DO - 10.1016/j.echo.2005.10.007
M3 - Journal article
C2 - 16500496
SN - 0894-7317
VL - 19
SP - 322
EP - 328
JO - Journal of the American Society of Echocardiography
JF - Journal of the American Society of Echocardiography
IS - 3
ER -