Abstract
Reliability of magnetic resonance (MR) velocity mapping to assess severity of stenosis was assessed in vitro. Steady flow at different flow rates through five stenoses with a central orifice area ranging from 17 to 176 mm2 was measured with velocity mapping performed perpendicular to the stenotic jet. Besides determination of the stenotic cross-sectional area and flow rate, the pressure gradient was calculated with the modified Bernoulli equation and compared with manometer measurements. Cross-sectional areas were measured with an accuracy of > or = 76%, a precision of > or = 91%, and an error of < or = 19 mm2. Flow rates had an accuracy of > or = 72%, a precision of > or = 94%, and an error of < or = 1.4 L/min. The modification of the Bernoulli equation limited its reliability to stenoses with areas of 35-113 mm2. Pressure gradients were calculated with an accuracy of > or = 80%, a precision of > or = 88%, and an error of < or = 15 mm Hg. The method was applied in a single patient with aortic stenosis and gave estimates that agreed with those obtained by heart catheterization.
Bidragets oversatte titel | Accuracy and precision of MR velocity mapping in measurement of stenotic cross-sectional area, flow rate, and pressure gradient. |
---|---|
Originalsprog | Engelsk |
Tidsskrift | Journal of Magnetic Resonance Imaging |
Vol/bind | 3 |
Udgave nummer | 2 |
Sider (fra-til) | 433-437 |
Antal sider | 5 |
ISSN | 1053-1807 |
Status | Udgivet - 1993 |