A radio-high-performance liquid chromatography dual-flow cell gamma-detection system for on-line radiochemical purity and labeling efficiency determination

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Separation of steroid isomers by ion mobility mass spectrometry

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Molecular genetic analysis using targeted NGS analysis of 677 individuals with retinal dystrophy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Recurrent, Activating Variants in the Receptor Tyrosine Kinase DDR2 Cause Warburg-Cinotti Syndrome

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. The CAPOS mutation in ATP1A3 alters Na/K-ATPase function and results in auditory neuropathy which has implications for management

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Praktisk oftalmologi

    Publikation: Bidrag til bog/antologi/rapportBidrag til bog/antologiForskningpeer review

Vis graf over relationer

In this study, a method of determining radiochemical yield and radiochemical purity using radio-HPLC detection employing a dual-flow-cell system is evaluated. The dual-flow cell, consisting of a reference cell and an analytical cell, was constructed from two PEEK capillary coils to fit into the well of a NaI(Tl) detector. The radio-HPLC flow was directed from the injector to the reference cell allowing on-line detection of the total injected sample activity prior to entering the HPLC column. The radioactivity eluted from the column was then detected in the analytical cell. In this way, the sample will act as its own standard, a feature enabling on-line quantification of the processed radioactivity passing through the system. All data were acquired on-line via an analog signal from a rate meter using chromatographic software. The radiochemical yield and recovery could be simply and accurately determined by integration of the peak areas in the chromatogram obtained from the reference and analytical cells using an experimentally determined volume factor to correct for the effect of different cell volumes.