TY - JOUR
T1 - A dynamic reference change value model applied to ongoing assessment of the steady state of a biomarker using more than two serial results
AU - Lund, Flemming
AU - Hyltoft Petersen, Per
AU - Fraser, Callum G
PY - 2019
Y1 - 2019
N2 - BACKGROUND: Reference change values are used to assess the significance of a difference in two consecutive results from an individual. Reference change value calculations provide the limits for significant differences between two results due to analytical and inherent biological variations. Often more than two serial results are available. Using the reference change value concept on more than two measurements results in an increased number of false-positive results. This problem has been solved for both uni- and bidirectional differences through use of wider limits when additional results are included.METHODS: Based on normally (Gaussianly) distributed simulated data, a dynamic reference change value model was developed using more than two results and total coefficients of variation. The dynamic reference change value model includes validation of a set-point as the mean of the four first serial results and additional results are assessed for compliance to the steady state with the same set-point. Furthermore, the dynamic reference change value model compensates for increasing false-positive results with subsequent results. The dynamic reference change value model was designed to calculate significant limits for bidirectional differences.RESULTS: Reference change factors were calculated for multiplication of the mean of previous results to create the limits for significant differences. The reference change factors are provided as a function of number of results and total coefficients of variation both in tables and in figures.CONCLUSIONS: The dynamic reference change value model is appropriate for ongoing assessment of the steady state of a biomarker using more than two serial results.
AB - BACKGROUND: Reference change values are used to assess the significance of a difference in two consecutive results from an individual. Reference change value calculations provide the limits for significant differences between two results due to analytical and inherent biological variations. Often more than two serial results are available. Using the reference change value concept on more than two measurements results in an increased number of false-positive results. This problem has been solved for both uni- and bidirectional differences through use of wider limits when additional results are included.METHODS: Based on normally (Gaussianly) distributed simulated data, a dynamic reference change value model was developed using more than two results and total coefficients of variation. The dynamic reference change value model includes validation of a set-point as the mean of the four first serial results and additional results are assessed for compliance to the steady state with the same set-point. Furthermore, the dynamic reference change value model compensates for increasing false-positive results with subsequent results. The dynamic reference change value model was designed to calculate significant limits for bidirectional differences.RESULTS: Reference change factors were calculated for multiplication of the mean of previous results to create the limits for significant differences. The reference change factors are provided as a function of number of results and total coefficients of variation both in tables and in figures.CONCLUSIONS: The dynamic reference change value model is appropriate for ongoing assessment of the steady state of a biomarker using more than two serial results.
KW - assessment of homeostatic set-point
KW - Assessment of steady state
KW - false-positive results
KW - monitoring
KW - normal (Gaussian) distribution
KW - reference change value
KW - several serial results
UR - http://www.scopus.com/inward/record.url?scp=85062336240&partnerID=8YFLogxK
U2 - 10.1177/0004563219826168
DO - 10.1177/0004563219826168
M3 - Journal article
C2 - 30803249
SN - 0004-5632
VL - 56
SP - 283
EP - 294
JO - Annals of Clinical Biochemistry
JF - Annals of Clinical Biochemistry
IS - 2
M1 - 4563219826168
ER -