A Comparison Study of Vector Velocity, Spectral Doppler and Magnetic Resonance of Blood Flow in the Common Carotid Artery

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Medical Student Ultrasound Education: A WFUMB Position Paper, Part I

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Respiratory variability of peak velocities in the common femoral vein estimated with vector flow imaging and Doppler ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Accuracy and Precision of a Plane Wave Vector Flow Imaging Method in the Healthy Carotid Artery

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Elastografie in der Brustbildgebung

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Dynamic soft tissue changes in the orbit after a blowout fracture

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. History and Latest Advances in Flow Estimation Technology: From 1-D in 2-D to 3-D in 4-D

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

Vis graf over relationer

Magnetic resonance phase contrast angiography (MRA) is the gold standard for blood flow evaluation. Spectral Doppler ultrasound (SDU) is the first clinical choice, although the method is angle dependent. Vector flow imaging (VFI) is an angle-independent ultrasound method. The aim of the study was to compare VFI- and SDU-estimated peak systolic velocities (PSV) of the common carotid artery (CCA) with PSV obtained by MRA. Furthermore, intra- and inter-observer agreement was determined. MRA estimates were significantly different from SDU estimates (left CCA: p < 0.001, right CCA: p < 0.001), but not from VFI estimates (left CCA: p = 0.28, right CCA: p = 0.18). VFI measured lower PSV in both CCAs compared with SDU (p < 0.001) with improved precision (VFI: left: 24%, right: 18%; SDU: left 38%, right: 23%). Intra- and inter-observer agreement was almost perfect for VFI and SDU (inter-observer correlation coefficient: VFI 0.88, SDU 0.91; intra-observer correlation coefficient: VFI 0.96, SDU 0.97). VFI is more accurate than SDU in evaluating PSV compared with MRA.

OriginalsprogEngelsk
TidsskriftUltrasound in Medicine & Biology
Vol/bind44
Udgave nummer8
Sider (fra-til)1751-1761
Antal sider11
ISSN0301-5629
DOI
StatusUdgivet - aug. 2018