Research
Print page Print page
Switch language
Bispebjerg Hospital - a part of Copenhagen University Hospital
Published

Validity and reliability of an ultrasound measurement of the free length of the Achilles tendon

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Characteristics of patients reporting symptoms by open-ended questions in specialist palliative care

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Medication errors in residential facilities based on Danish Poison Information Center inquiries

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Prognostic factors of 90-day mortality in patients hospitalised with COVID-19

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Dehydration as referral diagnosis to a medical admittance department

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. Prevention of anastomotic leak following surgical treatment for rectal cancer

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Positional changes in lumbar disc herniation during standing or lumbar extension: a cross-sectional weight-bearing MRI study

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. UTE T2* mapping of tendinopathic patellar tendons: an MRI reproducibility study

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

INTRODUCTION: Valid length measurements of the different segments of the Achilles tendon are needed in order to investigate if differential elongation of the Achilles tendon takes place after rupture. The purpose of this paper was to present data concerning the accuracy and reliability of an ultrasound measurement of the free part of the Achilles tendon.

METHODS: Both legs of 19 non-injured subjects were examined by magnetic resonance imagining (MRI) and ultrasound. The length from the distal tip of the soleus muscle to the tendon insertion on the calcaneus was measured by three independent ultrasound examiners. Repeated ultrasound measurements were performed and compared with MRI measurements. Intra-rater and inter-rater reliability and the agreement between MRI and ultrasound were determined. Data were evaluated using the intraclass correlation coefficient (ICC), the standard error of the measurement (SEM) and the minimal detectable change (MDC).

RESULTS: The measurement showed excellent intra-rater reliability (ICC = 0.94 (95% confidence interval (CI): 0.91-0.96), SEM = 5 mm and MDC = 13 mm) and inter-rater reliability (ICC = 0.96 (95% CI: 0.93-0.97), SEM = 4 mm and MDC = 11 mm). On average, ultrasound measurements exceeded the MRI measurements by 2 mm (non-significant), resulting in a measurement error of 5%.

CONCLUSIONS: The ultrasound measurement of the free part of the Achilles tendon showed good reliability and accuracy. For comparison between groups of non-injured subjects, differences of > 5 mm can be detected. For repeated assessment of individual subject differences ≥ 13 mm can be detected.

FUNDING: none.

TRIAL REGISTRATION: Institutional Review Board of Zealand, Denmark, Ref. no: SJ-318.

Original languageEnglish
Article numberpii: A5453
JournalDanish Medical Journal
Volume65
Issue number3
ISSN1603-9629
Publication statusPublished - Mar 2018

    Research areas

  • Achilles Tendon/anatomy & histology, Adult, Denmark, Female, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Reproducibility of Results, Tendon Injuries/diagnostic imaging, Ultrasonography

ID: 55649943