Research
Print page Print page
Switch language
Bispebjerg Hospital - a part of Copenhagen University Hospital
Published

Comparison between temporal and rectal temperature measurement

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Palytoksinforgiftning relateret til saltvandsakvarie

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Kryptoglandulære analfistler: Kryptoglandulære analfistler

    Research output: Contribution to journalReviewResearchpeer-review

  3. Non-motoriske symptomer ved Parkinsons sygdom

    Research output: Contribution to journalReviewResearchpeer-review

  4. Vaccination mod COVID-19 bør tilbydes ammende kvinder i Danmark

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. Diagnostik af bulløse hudsygdomme

    Research output: Contribution to journalJournal articleCommunication

  1. Clinical Applicability of Lung Ultrasound Methods in the Emergency Department to Detect Pulmonary Congestion on Computed Tomography

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Commentary on "Predictors of Acute Kidney Injury After Hip Fracture in Older Adults"

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Predictors of Acute Kidney Injury After Hip Fracture in Older Adults

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. New clinical guidelines on the spinal stabilisation of adult trauma patients - consensus and evidence based

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations
Introduction – Various digital thermometers for non-invasive use have been used increasingly in Danish hospitals, including the Temporal Artery Thermometer (TAT). However, previous studies have concluded that the accuracy of the TAT is unsatisfying at paediatric, surgical, cancer and intensive care patients. The purpose of this study was to compare the accuracy of the TAT to a conventional rectal thermometer within acutely admitted medical patients at the Emergency Department.
Method - The study was designed as a prospective, comparative research. For two months, 381 patients were included. With no more than 7 minutes apart the temperature was measured first with an Exergen TAT-5000 and then controlled with a rectal thermometer from Omron MC-341-E. The measurements were analysed in a Bland-Altman plot, and the sensitivity and specificity of the TAT were calculated.
Result – The differences between TAT and rectal thermometer spread from -1.7°C – 1.7°C. The mean of the differences was drawn in the Bland-Altman plot through 0.17 with a standard deviation at 0.47. The sensitivity and specificity were calculated to 67 % and 96 %, respectively.
Conclusion – Based on this study, we do not recommend the use of TAT as an alternative to rectal thermometer for non-invasive measuring of the body temperature in acutely admitted medical patients.
Funding and trial registration - All authors received honoraria from The Region Capital of Denmark. Study procedures were approved by the local ethical committee and submitted to www.clinicaltrials.org (NCT01817881).
Translated title of the contributionSammenlignende undersøgelse af temporal arterie termometer og rektal termometer for voksne i Akutmodtagelsen
Original languageEnglish
Article numberA04200270
JournalUgeskrift for Læger
Volume67
Issue number11
ISSN0041-5782
Publication statusPublished - 20 Oct 2020