Forskning
Udskriv Udskriv
Switch language
Bispebjerg Hospital - en del af Københavns Universitetshospital
Udgivet

Contrast-enhanced ultrasound using bolus injections of contrast agent for assessment of postprandial microvascular blood volume in human skeletal muscle

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Myocardial perfusion assessed with cardiac computed tomography in women without coronary heart disease

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. I-MIBG imaging for detection of anthracycline-induced cardiomyopathy

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  3. A reassessment of the blood-brain barrier transport of large neutral amino acids during acute systemic inflammation in humans

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Sphenopalatine ganglion stimulation induces changes in cardiac autonomic regulation in cluster headache

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Methods capable of measuring blood flow in a tissue-specific manner are needed. The purpose of this study was to investigate whether contrast-enhanced ultrasound (CEUS) using bolus injections of SonoVue® is an useful method for assessing postprandial changes in microvascular perfusion in the vastus lateralis muscle. Ten healthy, young subjects were recruited for this study. Six subjects participated in washout and reproducibility protocols to assess washout time of SonoVue® and the reproducibility of the method when measuring microvascular blood volume (MBV). Six subjects (two of which also participated in the washout and reproducibility protocols) participated in exercise and nutrition protocols, to assess the ability of the method to detect changes in MBV in response to these interventions. Intraday variation (coefficients of variation) for MBV indices, as assessed by peak signal intensity (PI) or mean plateau signal intensity (mPI), was high (PI: 19 ± 4·2%; mPI: 23 ± 3·3%). The exercise protocol induced significant increases in MBV indices (PI:+113%, P˂0·0001; mPI:+218%, P˂0·0001) acutely after exercise cessation. There were no changes in MBV indices in response to feeding during the nutrition protocol (PI: P = 0·51; mPI: P = 0·51). We conclude that CEUS using bolus injections of SonoVue® is not capable of detecting changes in MBV of vastus lateralis in response to feeding. This is probably due to the low reproducibility of the method. However, the method is capable of measuring changes in MBV in response to exercise. This method could therefore be used when investigating exercise-induced changes in microvascular perfusion.

OriginalsprogEngelsk
TidsskriftClinical Physiology and Functional Imaging
Vol/bind38
Udgave nummer5
Sider (fra-til)864-871
Antal sider8
ISSN1475-0961
DOI
StatusUdgivet - sep. 2018

ID: 56334415